Fixed frequency pulse magnetron ,The data should be read in conjunction with the Magnetron Preamble.
FEATURES
- The anode temperature must be kept below the limit specified by means of a suitable flow of air over the anode body.
- Measurements taken ‘as read’ using suitably calibrated equipment.
- Measured with heater voltage of 6.3 V and no anode input power, the heater current limits are 1.1 A minimum,1.4 A maximum.
- Tolerance ± 30%.
- Other frequency ranges can be supplied on request.
Specifications
- Operating frequency :3050 ± 10 MHz
- Typical peak output power:30 kW
- Magnet: integral
- Cathode : indirectly heated
- Anode voltage (peak):8.0 8.0 kV
- Output power (peak):30 30 kW
- Output power (mean):16.5 8.4 W